Whether youre mixing and granulating compounds in a pharmaceutical facility or working with combustible gases in the oil and gas industry, 3M Versaflo The TR-800 motor/blower with TR-830 battery is intrinsically safe (IS) equipment is essential.* Available in assemblies or ready-to-use kits with everything your team needs to get started. The 3M Versaflo Powered Air Purifying Respirator TR-800 Motor/Blower, with the 3M Battery Pack TR-830 attached, has been tested and classified for intrinsic safety in Haza
- Battery includes a bumper to help absorb impact; mechanical attachment of the battery helps prevent removal during use
- Audible and visual alarms alert users to low battery and low air flow
- Loose-fitting headgear can help accommodate workers with limited facial hair and prescription eyewear
- Compatible with particulate only filters or particulate and gas and vapor combination cartridges for protection in a variety of environments
Product Dimensions |
Imperial | Metric |
| Weight | 0 NULL | |
|---|---|---|
| Width | 0 null | |
| Length | 0 null | |
| Height | 0 null |
Shipping Dimensions |
|
| Weight | 7.9563 lb |
|---|---|
| Length | 16.75 in |
| Width | 12.3748 in |
| Height | 10.6248 in |
PRODUCT FAQ
-
bsolutely, I'd be happy to help with that.
What makes the 3M™ Versaflo™ Powered Air Purifying Respirator Easy Clean Kit TR-800-ECK stand out from other options on the market?
-
The TR-800-ECK is designed for durability and ease of cleaning, with its smooth surface and large corner pockets making it simple to wipe clean. It also offers a high level of respiratory protection with a range of filters available.
Can you tell me more about the battery life of the TR-800-ECK kit?
-
The rechargeable lithium-ion battery in this kit provides up to 12 hours of use on a single charge, ensuring long-lasting performance for extended wear.
How does the comfort factor compare when wearing the Versaflo respirator for longer periods of time?
-
The design features adjustable airflow levels and an ergonomic belt that distributes weight evenly, promoting comfort during extended use. Users often find it comfortable even when worn for prolonged periods.
Is maintenance difficult for this powered air purifying respirator kit?
-
Maintenance is made easy with tool-free assembly and disassembly along with intuitive indicators that show when components need changing or cleaning. This helps ensure optimal performance while simplifying upkeep tasks.
The TR-800-ECK is a complete Powered Air Purifying Respirator designed to provide respiratory protection in pharmaceutical manufacturing environments. It features an Intrinsically Safe (IS) motor/blower that is certified by UL with an IS rating of Division 1: IS Class I, II, III under standard UL 60079, 6th Edition, 2013. This ensures the highest level of safety for users.
The respirator includes various components to ensure comprehensive protection. The S-433L Hood with Integrated Head Suspension provides a comfortable and secure fit. The BT-30 Length Adjusting Breathing Tube allows for easy adjustment to suit individual needs. The TR-6710N (HE) Filter is NIOSH approved and effectively filters out particulates that may be present in the air.
In addition, the TR-800-ECK comes with the TR-641N Single Station Battery Charger, BT-922 Breathing Tube Cover, TR-802N Intrinsically Safe PAPR Unit, TR-830 Intrinsically Safe Battery, TR-838 Battery Attachment Tool, TR-627 Easy Clean Belt, TR-6700 Filter Cover, TR-6600 Prefilter (x2), TR-662 Spark Arrestor (x2), TR-653 Storage and Cleaning Kit, and TR-971 Airflow Indicator. These accessories enhance the functionality and usability of the respirator.
It is important to note that respirators are designed to protect against specific airborne contaminants. Users must carefully read and understand the User Instructions provided with the product before use. Compliance with local regulations is essential, including the implementation of a written respiratory protection program that meets the requirements of OSHA 29 CFR 1910.134 in the U.S. In Canada, the CSA standards Z94.4 requirements must be met, along with the requirements of the applicable jurisdiction.
Misuse of the TR-800-ECK Powered Air Purifying Respirator can have serious consequences, including sickness or death. To ensure correct use, it is recommended to consult a supervisor, refer to the User Instructions, or contact 3M Personal Safety Division (PSD) Technical Service for assistance. In the U.S., the contact number is 1-800-243-4630, and in Canada, it is 1-800-267-4414.
It is important to understand that 3M industrial and occupational products, including the TR-800-ECK, are specifically intended for sale to trained industrial and occupational customers for workplace use. They are not intended for sale or use by consumers for personal or recreational purposes. These products must be selected and used in compliance with applicable health and safety regulations and standards, such as U.S. OSHA and ANSI, as well as all product literature, user instructions, warnings, and limitations. Misuse of 3M industrial and occupational products can result in injury, sickness, or even death. For assistance with product selection and use, it is recommended to consult an on-site safety professional, industrial hygienist, or other subject matter expert.